6 Maintenance by the operator

6.1.6 Using the centralized greasing system

The timer is triggered at machine startup and stops at the machine's complete shutdown.
When the ignition switch is turned off, the elapsed time before the next lubrication is saved and
the timer restarts with this value when the machine is restarted.
To refill the centralized greasing system, connect the grease pump on the filling connector
nipple (B).
Do not plug the hole at the top of the tank in order not to block the filling.
In case of over filling, the tank can burst and cause physical injuries.
It is possible to manually start a lubrication in order to ensure proper greasing pump operation
or if the machine needs an additional lubrication:
– Press the switch in the cab.
– Press the button located under both switches for 2 seconds until the LED on the right comes
on.
Note
To access the timer, remove the cap located below the grease tank.
The lubrication cycle is shortened and the lubrication starts normally. Once the lubrication
is carried out, the lubrication cycle restarts at zero.