Checking the electrical system

TIP
Before checking the electrical system, make
sure that the battery voltage is at least 12 V.
ECA14371
NOTICE
Never insert the tester probes into the cou-
pler terminal slots. Always insert the probes
from the opposite end "a" of the coupler, tak-
ing care not to loosen or damage the leads.
a
a
1-53
BASIC SERVICE INFORMATION
ECA16640
NOTICE
For waterproof couplers, never insert the
tester probes directly into the coupler. When
performing any checks using a waterproof
coupler, use the specified test harness or a
suitable commercially available test har-
ness.

Checking the connections

Check the leads, couplers, and connectors for
stains, rust, moisture, etc.
1. Disconnect:
• Lead
• Coupler
• Connector
ECA16780
NOTICE
• When disconnecting a coupler, release the
coupler lock, hold both sections of the cou-
pler securely, and then disconnect the cou-
pler.
• There are many types of coupler locks;
therefore, be sure to check the type of cou-
pler lock before disconnecting the coupler.
ECA16790
NOTICE
When disconnecting a connector, do not pull
the leads. Hold both sections of the connec-
tor securely, and then disconnect the con-
nector.