These venting systems, in combination with the CB72EPV Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Intertek.
The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Locations" section.
Regency
Direct Vent (Flex) System Termination Kits include all the parts needed to install the CB72EPV using a flexible vent.
®
Notes:
1. Only Flex pipe purchased from Regency
for Flex installations
2. Horizontal vent must be supported every 3 feet.
3. Regency
Direct Vent System (Flex) is only approved
®
for horizontal terminations.
4. Flex system can only be used up to a maximum vent
length of up to 40 feet using up to 2 x 20 ft flex kits (Part
# 946-756). If longer runs are required, rigid pipe must
be used.
5. Reducer (946-758) must be used in all applications when