Locating Your
Gas Fireplace - Bay Install
1. When selecting a location for your fireplace,
ensure that the clearances are met.
2. The appliance must be installed on a flat, solid,
continuous surface For example a wood, metal
or concrete floor or in a raised (on the wall) ap-
plication. The appliance must be installed on
a metal or wood panel extending the full width
and depth of the appliance.
3. The CB72EPV Direct Vent Gas Fireplace can
be installed framed out into the room as in D
and E. See Diagram 1.
E
Diagram 1
D)
3 sided-CB72EPV (corner install)
E) 3 sided-CB72EPV
4. For bedroom installations, check with local
codes before installation. This appliance is
offered with a remote control.
5. The CB72EPV Direct Vent Gas Fireplace is
approved for alcove installations, see "Clear-
ances" section for details.
6. We recommend that you plan your installa-
tion on paper using exact measurements for
clearances and floor protection before actually
installing this appliance. Have an authorized
inspector, dealer, or installer review your plans
before installation.
Note:
For vent terminations refer to "Exterior V ent
Termination Locations" section.
Locating Your
Gas Fireplace - Corner Install
1. When selecting a location for your fireplace,
ensure that the clearances are met.
2. The appliance must be installed on a flat, solid,
continuous surface For example a wood, metal
or concrete floor or in a raised (on the wall) ap-
plication. The appliance must be installed on
a metal or wood panel extending the full width
and depth of the appliance.
3. The CB72EPV Corner Conversion Gas Fire-
place can be installed in a recessed position
or framed out into the room as in A and B. See
Diagram 1.
A
Diagram 1
A) Corner Left
B) Corner Right
4. For bedroom installations, check with local
codes before installation. This appliance is
offered with a remote control.
5. The CB72EPV Corner Conversion Gas Fire-
place is approved for alcove installations, see
"Clearances" section for details.
6. We recommend that you plan your installa-
tion on paper using exact measurements for
clearances and floor protection before actually
installing this appliance. Have an authorized
inspector, dealer, or installer review your plans
before installation.
Note:
For vent terminations refer to "Exterior
Vent Termination Locations" section.
installer's information