installation
CV72EPV / CB72EPV

Gas Power Vent Installation CB72EPV - Flex Pipe

Gas Power Vent Installation CV72EPV / CB72EPV - Flex Vent
The Power Vent System is a Direct Vent Terminal designed to allow installation of gas appliances where typical vent configurations cannot be achieved.
These installation instructions must be used in conjunction with the appliance and appropriate Power Vent components installation instructions.
120 Volt power supply is required to operate this system.
Models Equipped with Surefire Ignition
The Power Vent system can only be used with units that have been tested with the Regency Power Vent system.
Downward vertical vent runs are permitted with the Surefire Ignition system. See vent configuration in unit manual.
Reducer 5" x 8" to
4 " x 6-5/8"
(Required)
(sold separately)
CV72EPV Shown
946-535 Power Vent Kit with Vent Terminal
1
946-758
Reducer (required)
2 Max.
946-756
20' Flex Kit
1
Power Vent Fan
1
Power Vent Frame
1
911-250/P
45' 5-wire BX cable or
1
911-251/P
90' 5-wire BX cable
1
946-535
Power Vent Kit
| City Series CB72EPV
66
919-851a
BX Cable
(sold separately)
sold separately
sold separately
included w/Power Vent kit
included w/Power Vent kit
sold separately
sold separately
sold separately
2
Max. 2 x 20' Flex kits (946-756)
(sold separately)
Power Vent Terminal
(946-535)
Frame Assembly
(included w/Power Vent kit)
Power vent trim
Power vent frame
Power Vent frame
(adjustable depth)
(incl. with Power Vent
kit)
Power Vent trim
(incl. with Power Vent
kit)