Exterior Vent Termination Locations - Regency City CB72EPV-LP Owners & Installation Manual

Hide thumbs Also See for City CB72EPV-LP:
Table of Contents

Advertisement

Exterior Vent Termination Locations

Minimum Clearance Requirements
A
Clearance above grade, veranda, porch, deck, or balcony
B
Clearance to window or door that may be opened
C
Clearance to permanently closed window
D
Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm)
from the center line of the terminal (check with the local code)
E
Clearance to unventilated soffit
F
Clearance to outside corner: with PowerVent Termination Cap.
G
Clearance to inside corner: with PowerVent Termination Cap
H
Clearance to each side of center line extended above meter/regulator assembly
J
Clearance to service regulator vent outlet
K
Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance
L
Clearance to a mechanical air supply inlet
#3' (91cm) above if within 10' (3m) horizontally.
M
Clearance above paved sidewalk or a paved driveway located on public property
N
Clearance under veranda, porch, deck, or balcony
1
In accordance with current CSA B149.1, Natural Gas and Propane Installation Code
2
In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor
* Clearance in accordance with local installation codes and the requirements of the gas supplier
a
3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly
b
3 feet (91cm) above - if within 10 feet (3m) horizontally
B
Fixed Closed
B
M
F
C
A
Fixed Closed
E
D
B
K
A
A
Openable
Openable
A
Air Supply Outlet
Vent Termination
G
A
H
N
A
L
J
Area where terminal is not permitted
Canada
12"(30cm)
12"(30cm)
*
29"(74cm)
20"(51cm)
7"(18cm)
7"(18cm)
36"(90cm)
36"(90cm)
12"(30cm)
72"(1.8m)
84"(2.1m)
12"(30cm)
City Series CB72EPV |
installation
1
2
USA
12"(30cm)
9" (23cm)
*
29"(74cm)
20"(51cm)
7"(18cm)
7"(18cm)
a
*
*
9" (23cm)
b
36"(90cm)
*
*
55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

City cb72epv-ngCity cb72e power vent series

Table of Contents