CITY SERIES
5. Secure the unit with framing to the wall studs with 2-1/2"-3" wood screws
(not supplied). Use 8 screws and secure to 4 studs minimum. Ensure the
frame is also secured to the 2 additional studs spaced 77.5" apart, using
the last hole on the upper and lower Part B framing part as shown below.
Secure framing to wall
Note: only 2 additional studs shown (regular framing not shown)
6. Attach the 2 center supports (Part I ) to upper and lower Part B of the back
frame with 2 screws each as shown.
Part I
7. Attach the 4 x end pieces (Part J) to the upper and lower Part B of the
back frame with two screws each.
919-951a
8. Attach 2 x Part G to the previously installed Part J parts with 2 screws
9. Attach end cross braces (Parts E + F ) with 2 screws at each end as
screw
10. Install Part A (x2) to Part G on each side with 2 screws on each end.
Part J
2
at each end.
Part G
shown below.
Part E + F
Part A
installation
City Series CB72EPV |
01.24.19
41