Regency City CB72EPV-LP Owners & Installation Manual page 20

Hide thumbs Also See for City CB72EPV-LP:
Table of Contents

Advertisement

owner's information
5. Pull the 3 lower glass gasket pads forward to release the glass.
6. S upport the glass with one hand and open the 9 lower clamps.
Lower clamps (x9) in open position
7. L ocate the 2 levers below the glass and turn them both 90° in a clockwise
direction to lower the firebox glass panel.
Levers to lower firebox glass
| City Series CB72EPV
20
Gasket pad
Push down on levers to lower glass panel
8. C arefully lean glass forward onto supports.
Glass panel--leaning on supports
NOTE: The firebox glass may remain propped on the glass supports to clean
the interior surface. Use care when cleaning -- do not apply excessive force
or pressure.
9. T o remove the firebox glass panel from the unit: tilt the glass forward
gently onto the glass supports, grip both suction clamps and lift the glass
up and out of the unit.
10. To install glass--reverse steps.
IMPORTANT: Remove glass panel completely when installing or removing
panels, logs, media, etc. to avoid causing any damage to the glass.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

City cb72epv-ngCity cb72e power vent series

Table of Contents