Clearances CB72EPV - Bay Install

The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
fireplace and vent system be installed only in accordance with these instructions.
Clearance: single sided
A1: Mantel Height (min.)
A: From Floor
B: Sidewall (on one side) Min.
C: Enclosure Width (min.)
D: Mantel Depth (max.)
E: Alcove Width
F: Alcove Depth
G: Convection Air Outlet Opening Offset
H: Convection Air Outlet
I Enclosure Depth (min.)
J: Opening Height
K: To Ceiling (Min.) all 3 sides
L: Chase Enclosure (Min.)
Clearance to Sprinkler Head (Min.)
M:
Hearth
** See mantel clearances chart in this manual.
B
The HeatWave Duct Kit has differ-
ent clearance and framing require-
ments, check the HeatWave manual
for details.
Caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and vent
system be installed only in accordance with these instructions.
| City Series CB72EPV
30
Dimension
**
min. 0"
8" (203mm)
82-11/16" (2100mm)
**
120" (3048mm)
36" (914mm)
*0-2" (0-51mm)
*288 square inches
20-3/8" (517mm)
15-1/16" (383mm)
2-1/2" (64mm)
87" (2210mm)
36" (914mm)
0"
E
F
Alcove
WARNING
Measured From:
Top of Fireplace Opening
Bottom of Fireplace Opening
Side of Fireplace Opening
Minimum inside dimensions
Sidewall to Sidewall (Minimum)
Front to Unit (Maximum)
Max. offset from top of chase enclosure
Minimum inside dimensions
Bottom/Top of Fireplace Opening
To Top of Ceiling
From base of unit/floor to top of enclosure
Perpendicular from chase grill
No hearth required
Flue Clearances to Combustibles
Horizontal - Top
Horizontal - Side
Horizontal - Bottom
Vertical
Passing through wall/
floor/ceiling - when
firestop is used.
Note: This appliance uses 4" x 6-5/8" venting
Sprinkler
M
L
Chase grill
Side view
3"
2"
2"
2"
1-1/2"