Horizontal Terminations - Flex Vent 5" X 8 - Regency City CV60EPV-NG Owners & Installation Manual

Direct vent
Table of Contents

Advertisement

installation

Horizontal Terminations - Flex Vent 5" x 8"

These venting systems, in combination with the CV60E Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Intertek. The
location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Locations" section.
Regency
Direct Vent (Flex) System Termination Kits include all the parts needed to install the CV60E using a flexible vent.
®
FPI Kit #
Length Contains:
#946-615
4 Feet
1)
2)
3)
4)
#946-618
6 Feet
5)
6)
7)
#946-616
10 Feet
8)
9)
10) vinyl siding standoff
Notes:
1. Liner sections should be continuous without any joints
or seams.
2. Only Flex pipe purchased from Regency
for Flex installations
3. Horizontal vent must be supported every 3 feet.
4. Regency
Direct Vent System (Flex) is only approved
®
for horizontal terminations.
5. Flex system can only be used up to a maximum
continuous vent length of up to 10 feet. If longer runs
are required, rigid pipe must be used.
52 ............................................. |City Series CV60E-1
52 | City Series CV60E-1
8" flexible liner (Kit length)
5" flexible liner (Kit length)
spring spacers
thimble
AstroCap XL termination cap
screws
tube of Mill Pac
plated screws
S.S. screws #8 x 1-1/2" drill point
may be used
®
*Unit is not exactly as shown.
5" (127 mm)
8" (203 mm)
Vent Guard - if required*
(Part #946-604/P)

Advertisement

Table of Contents
loading

This manual is also suitable for:

City cv60e-1City seriesCity cv60e-ng

Table of Contents