Copy Of Safety Decal - Regency City CB72EPV-LP Owners & Installation Manual

Hide thumbs Also See for City CB72EPV-LP:
Table of Contents

Advertisement

safety decal
This is a copy of the label that accompanies Direct Vent Gas Fireplace. We have printed a copy of the
contents here for your review. The safety label is located on the front inside base of the unit, visible when
the outer front panel is removed.
NOTE: Regency
units are constantly being improved. Check the label on the unit and if there is a
®
difference, the label on the unit is the correct one.

Copy of Safety Decal

Listed/Nom: VENTED GAS FIREPLACE HEATER /
Certified to / Certifi :
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Refer to Intertek's Directory of Building Products for detailed information.
C # 4001172
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
NATURAL GAS: Model: CB72EPV-NG
Minimum supply pressure
Manifold pressure - High
Manifold pressure - Low
Orifice size
Maximum input
Minimum input
Altitude
PROPANE GAS: Model: CB72EPV-LP
Minimum supply pressure
Manifold pressure - High
Manifold pressure - Low
Orifice size
Maximum input
Minimum input
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.
This appliance is only for use with the type(s) of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by
local codes. See owner's manual for details. This appliance is supplied with a conversion kit.
L'appareil doit être installé conformément aux codes et règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation National Fuel Gas Code ANSI Z223.1, ou CSA-B149.1 Natural Gas and
Propane Installation Code en vigueur.
L'appareil doit être installé conformément à la norme CAN/CSA-Z240, Série MM, Maisons mobiles, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes ne sont pas
applicables, veuillez vous référer à la norme ANSI/NCSBCS A225.1/NFPA 501A.
Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique et peut être installé dans une maison préfabriquée (É.-U. seulement) ou mobile installée à demeure si les règlements
locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Une trousse de conversion est fournie avec cet appareil.
For Use Only with Barriers CB72E (Part #940-500/P,#940-502/P,#940-503/P) Follow installation instructions.
Utiliser uniquement avec l'écrans CB72E (n°940-500/P,n°940-502/P,n°940-503/P) Suivre les instructions d'installation.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
Electrical supply / Alimentation électrique 115VAC, 2.5A, 60Hz.
Part No. 946-556 Heatwave Kit may be used. Le système Heatwave (pièce n°946-556) peut être
VENTED GAS FIREPLACE - NOT FOR USE WITH SOLID FUELS.
FOYER AU GAZ À ÉVACUATION -
Model/Modèle :
CANADIAN ENERGY
CSA P.4.1 Fireplace Efficiency (FE) / Efficacité énergétique des foyers (EEF) CSA P.4.1
PERFORMANCE
VERIFIED
Natural Gas / Gaz naturel 63.39%
Propane Gas / Gaz propane 65.52%
RENDEMENT
ÉNERGÉTIQUE
EP5011169
VÉRIFIÉ
Part #:
919-889c
Colour:
Black on grey except what is indicated as being printed red.
For the State of Massachusetts, installation
Size:
(File at 100%) 9.11"w x 6.27"h
Material:
and repair must be done by a plumber or
Start serial sequence at 470000001
gas fitter licensed in the Commonwealth of
Massachusetts.
Aug. 2/18:
Created draft
Oct. 4/18:
Rev. A - Standard updated
For the State of Massachusetts, flexible con-
Nov. 20/18:
Rev. B - added efficiency
nectors shall not exceed 36 inches in length.
Jan. 29/19:
Rev C - remodeled decal + added ETL logo at the bottom
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
| City Series CB72EPV
6
é ANSI Z21.88-2017 • CSA-2.33-2017
CSA 2.17-2017
GAZ NATUREL : Modèle CB72EPV-NG
5.0"
WC/C.E. (1.25 kPa)
Pression d'alimentation minimale
3.5"
WC/C.E. (0.87 kPa)
Pression de sortie (manifold) - Haute
1.6"
WC/C.E. (0.40 kPa)
Pression de sortie (manifold) - Basse
# 30
DMS
Taille de l'orifice
46,500 Btu/h
(13.63 kW)
D bit calorifique maximal
é
32,000 Btu/h
(9.37 kW)
D bit calorifique minimal
é
0-4500
ft/pi
(0-1372 m)
Altitude
GAZ PROPANE : Modèle CB72EPV-LP
11"
WC/C.E. (2.73 kpa)
Pression d'alimentation minimale
Pression de sortie (manifold) - Haute
10"
WC/C.E. (2.49 kPa)
6.4"
WC/C.E. (1.59 kPa)
Pression de sortie (manifold) - Basse
Taille de l'orifice
# 47
DMS
45,500 Btu/h
(13.33kW)
D bit calorifique maximal
é
36,000 Btu/h
(10.55 kW)
D bit calorifique minimal
é
0-4500
ft/pi
(0-1372 m)
Altitude
NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE.
CB72EPV-NG
Duplicate S/N
FOYER AU GAZ À ÉVACUATION
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
DOIT ÊTRE UTILISÉ UNIQUEMENT AVEC LES PORTES VITRÉES CERTIFIÉES
utilisé.
CB72EPV-LP
470
Serial No./ No de série
470
Minimum Clearances to Combustibles /
Dégagement minimaux par rapport aux matériaux combustibles
Min. 288 in
2
Side Walls / Murs latéraux
A
Ceiling / Plafond
B
Min. Mantel Height /Hteur Min
B
Manteau
D
F
C 9" (229 mm) with 12" mantel
Max. Mantel Depth/Profondeur Max
A
C
Manteau
D
Alcove Width/Largeur Alcôve
E
E
Alcove Depth/Profondeur Alcôve
F
DOOR SEAL: Please
(See instruction manual for detailed instructions)
check that the door is
(Voir manuel pour plus de détails)
properly sealed
This vented gas fireplace heater is not for use with air filters.
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
FPI Fireplace Products International Ltd. Delta, BC, Canada
Made in Canada/ Fabriqué au Canada
8" (203 mm)
61-3/4" (1568mm)
12" (305 mm)
88" (2235 mm)
36" (2134 mm)
919-889c