Regency City CB72EPV-LP Owners & Installation Manual page 81

Hide thumbs Also See for City CB72EPV-LP:
Table of Contents

Advertisement

CITY SERIES
tooltip
12. Bend the arm of the aeration lever bracket up from 90° to straighten and
tooltip
release aeration lever (lever will come with the burner).
Bracket
Aeration
lever
13. Loosen 8 screws in locations shown below (2 at front and 2 at rear)—slide
burner to the left away from the orifice and lift out.
tooltip
tooltip
14. Remove burner orifice with a 3/8" wrench. Use another wrench to hold
on to the elbow behind the orifice. Discard orifice. Reinstall new burner
orifice LPG stamped #47 and tighten.
tooltip
15. Remove pilot retainer clip with pliers and pull off the pilot cap to expose
the pilot orifice.
Pilot retainer clip
920-069
CV72E shown
Burner screw locations
CV72E shown
Slide burner to the left and lift out
CV72E shown
Burner Orifice
Location
16. Unscrew the pilot orifice with the Allen key; then replace with the LPG
pilot orifice and the pilot cap, provided in the kit.
17. Reinstall pilot cap and pilot retainer clip.
18. Prior to installing burner—adjust aerations settings - to 3/8" for LP. Re-
install burner (see Step 11).
19. Ensure the pilot light is in the correct orientation to the Burner. Recon-
nect the gas and electrical supply to the appliance. Start the appliance.
(see section on Lighting Instructions) Ensure that pilot and burner igni-
tion is completed without delay. Check both your inlet and outlet pres-
sures at full load. With a soapy solution, leak test the entire system.
Verify both the correct flame and pilot appearance.
20. See Gas Pipe Pressure Testing in manual.
NG SYSTEM DATA
Min. Supply Pressure
Manifold Pressure - High
Manifold Pressure - Low
Orifice Size
Maximum Input
Minimum Input
Altitude
Installer Notice:
These instructions must be left
with the appliance
2
installation
City Series
11" WC (2.73kpa)
10" WC (2.49 kpa)
6.4" WC (1.59 kpa)
#47 DMS
45,500 Btu/h (13.33 kW)
36,000 Btu/h (10.55 kW)
0-4500 ft (0-1372m)
.
02.21.19
City Series CB72EPV |
81

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

City cb72epv-ngCity cb72e power vent series

Table of Contents