LP Conversion Instructions

This conversion kit shall be installed by a qualified ser-
vice agency in accordance with the manufacturer's in-
structions and all applicable codes and requirements
of the authority having jurisdiction. If these instructions
is not followed exactly, a fire, explosion or production
of carbon monoxide may result causing property dam-
age, personal injury or loss of life. The qualified service
agency is responsible for the proper installation of this
kit. The installation is not proper and complete until
the operation of the converted appliance is checked as
specified in the manufacturer's instructions supplied
with the kit.
Conversion Kit 666-977 includes:
1
911-011
Stepper Motor LP for 885 SIT
1
905-014
Orifice #47
1
910-037
Pilot Orifice #30
1
918-590
Decal - Conversion to LP
1
908-528
Label Propane
1
904-529
5/32" long Allen Key
1
920-069
Instruction Sheet
Caution: The gas supply shall be shut off prior to disconnecting the
electrical power, before proceeding with the conversion.
Always let the appliance cool to room temperature before servicing.
1 Remove the outer panels and safety glass — see manual.
2. Remove inner firebox glass — see manual.
3. Remove inner panels — see manual.
4. Remove all media installed on burner (glass, logs or stones, etc).
5. Lift off the far right base panel and loosen 2 screws on IFC cover--re-
moved cover to access IFC.
920-069
| City Series CB72EPV
80
CONVERSION FROM NG TO LP
CV72E-11 using SIT 885 NOVA Gas Valve
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION!
WARNING
CB72E shown
6. Disconnect the Cable coming from the Pressure Regulator Motor.
7. Remove and discard 2 Pressure regulator screws (A)using a (T20 or slot
screwdriver,) Pressure Regulator (B) and Spring and Diaphragm (C)
(see below).
8. Ensure the rubber gasket, which is prefitted as part of the Assembly,
is properly positioned. Install the new Pressure Regulator using the 2x
M4 x .7 screws supplied. Tighten the screws to 25lb-in. In the event that
the screw threads are cross threaded or stripped, replace the valve as-
sembly.
Install the enclosed propane identification label to the valve body where it
can be easily seen.
Pressure
regulator
screws
tooltip
9. Re-attach the Pressure Regulator wire (disconnected in Step 6), and re-
situate the IFC, secure the screws that fasten the IFC Mounting Brackets.
10. Remove pilot hood by lifting up and off.
Pilot hood
Base Panel
11. Remove the trim cover on right side of burner by lifting off. Also remove
the burner surround by sliding to the left and lifting off.
IFC cover
Trim cover
1
CITY SERIES
Cable from motor
Burner Surround