installation
Heatwave Deflector + Heatwave Venting Installation
NOTE: Install the Heatwave venting to the unit before moving unit into
framing to allow access to the back screws.
1. Remove the deflector from the top of the unit by removing 4 screws.
2. Remove the knockout from the top of the unit and recycle.
3. Fold up 3 tabs up as shown.
4. Connect pipe adaptor with 3 screws (use the lower holes on the adaptor).
| City Series CB72EPV
74
5. Connect the flex pipe to the adaptor with 3 screws.
6. Fold the deflector (removed from Step 1) fold the 4 tabs to 90° and secure
the tabs to the unit with 4 screws.