Framing Dimensions Cb72Epv - Bay Install - Regency City CB72EPV-LP Owners & Installation Manual

Hide thumbs Also See for City CB72EPV-LP:
Table of Contents

Advertisement

installation

Framing Dimensions CB72EPV - Bay Install

NOTE: Framing may be constructed of combustible material (ie. 2 x 4)and does not require steel studs.
Framing
Description
Dimensions
A
Framing Height
B
Framing Width
C*
Framing Depth
D
Minimum Height to Combustibles
G
Vent Centerline Height
**
Gas Connection Opening Height
**
Gas Connection Height
**
Gas Connection Inset-Centre Opening
C* - see not in diagram below
** See manual for alternate Gas/ Electrical connection options
Ensure that the wood base that the appliance will sit on is strong enough to support the full weight of this appliance.
The overall weight of this appliance is 582 pounds (shipping weight).
Note: A combined minimum
of 288 square inches of open
area is required for the con-
vection air outlet to cool the
enclosure. Ensure clearances
for Convection Air Outlets
are met.
See clearances CB72EPV in
this manual as there are dif-
ferent methods as to how this
can be achieved.
Note: T his appliance must be
installed on a solid surface
such as a plywood floor
which must be the full width
and depth of the appliance.
| City Series CB72EPV
34
CB72EPV
51" (1295mm)
82-11/16" (2100mm)
20-5/8" (524mm)
87"(2210mm)
55-1/4" (1403mm)
See gas connection location in this manual
See gas connection location in this manual
See gas connection location in this manual
Note: Unit must be installed onto a solid
backwall - do not install directly onto studs.
*C
Note : The framing depth does not take into
account drywall/wood or similar materials
against the back wall. The framing depth will
need to change based on the thickness of
the material (example: 20 5/8 framing depth
+ 1/2 drywall = 21 1/8")