installation
Description
Attic Insulation Shield 12"
Attic Insulation Shield
- Cold Climates 36"
Wall Firestop
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
(L)
Run (X)
0" (0mm)
4-7/8" (124mm)
6" (152mm)
8" (203mm)
9" (229mm)
10-1/8" (257mm)
12" (305mm)
12-1/4" (311mm)
24" (610mm)
20-5/8" (524mm)
36" (914mm)
29" (737mm)
48" (1219mm)
37-7/16" (951mm)
Note: Horizontal runs of vent must be level, or have a 1/4" rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high temperatures and may present a possible fire hazard.
| City Series CB72EPV
58
Selkirk
Simpson
Direct Temp™
Direct Vent Pro
®
46DVA-IS
N/A
N/A@ FPI
N/A
N/A
46DVA-WFS
N/A
4" x 6-5/8" Venting
Rise (Y)
13-7/8" (340mm)
16-1/2" (419mm)
18-5/8" (473mm)
20-3/4" (527mm)
29-1/8" (740mm)
37-1/2" (953mm)
45-15/16" (1167mm)
American Metal
Metal-Fab™
Products®
Sure Seal
Amerivent Direct
4DAIS12
N/A
4DAIS12
N/A
N/A
N/A
For specific instructions on venting components - visit the
manufacturers website listed below.
Simpson Direct Vent Pro: www.duravent.com
Selkirk Direct-Temp: www.selkirkcorp.com
American Metal Products: www.americanmetalproducts.com
Metal-Fab Sure Seal: www.mtlfab.com
Security Secure Vent: www.securitychimneys.com
Industrial Chimney Company: www.icc-rsf.com
Olympia Ventic DV: www.olympiachimney.com
Security
ICC Excel
Olympia
Ventis DV*
Secure- Vent®
Direct
SV4RSA
N/A
VDV-AIS04
N/A
TM-4AS
N/A
N/A
TM-4TR
VDV-FS04