operating instructions

Aeration Adjustment

The burner aeration is factory set but may need adjusting due to either the
local gas supply or altitude. Open the air shutter for a blue flame or close for
a more yellow flame.
Note: If the firebox glass, logs, inner panels, etc. are already installed, the
aeration can be adjusted from outside the firebox.
1. R emove the centre access panel on the outer trim, if finishing material is
already installed, remove the glass safety barrier and center outer panel--
see instructions in this manual.
Remove
2. L oosen 2 screws on the aeration lever access door. Lift the door up and
out to remove.
3. A ttach the handle to the aeration lever through the access opening--handle
will slide into position on the lever.
NOTE: The aeration handle is located near the right hand side of the gas valve
access door -- attached by a magnet.
104 | City Series CB72EPV
Aeration access door
Aeration adjustment
handle
4. Adjust aeration accordingly.
Pushing lever in -- closes the air shutter.
Pulling the lever outward -- opens the air shutter.

Minimum Air Shutter Opening

NG
3/16"
NG with Logs
3/16"
NG with Stones
3/16"
LP
3/8"
LP with Logs
3/8"
LP with Stones
3/8"
Note: Any damage due to carboning resulting from improperly setting the
aeration controls is NOT covered under warranty.
5. R emove the handle by lifting up and out--replace the access door and tighten
the 2 screws. Hang the handle back onto the magnet.
6. Reverse Step 1.
Aeration adjustment video