Copy Of Safety Decal; Decal Location - Regency City CV60EPV-NG Owners & Installation Manual

Direct vent
Table of Contents

Advertisement

safety decal
This is a copy of the label that accompanies Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located
on the front inside base of the unit, visible when the outer front panel is removed.
NOTE: Regency
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
®

Copy of Safety Decal

Listed/Nom: VENTED GAS FIREPLACE HEATER /
Certified to / Certifi :
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Refer to Intertek's Directory of Building Products for detailed information.
C # 4001172
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
NATURAL GAS: Model: CV60E-NG1
Minimum supply pressure
Manifold pressure - High
Manifold pressure - Low
Orifice size
Maximum input
Minimum input
Altitude
PROPANE GAS: Model: CV60E-LP1
Minimum supply pressure
Manifold pressure - High
Manifold pressure - Low
Orifice size
Maximum input
Minimum input
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.
This appliance is only for use with the type(s) of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by
local codes. See owner's manual for details. This appliance is supplied with a conversion kit.
L'appareil doit être installé conformément aux codes et règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation National Fuel Gas Code ANSI Z223.1, ou CSA-B149.1 Natural Gas and
Propane Installation Code en vigueur.
L'appareil doit être installé conformément à la norme CAN/CSA-Z240, Série MM, Maisons mobiles, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes ne sont pas
applicables, veuillez vous référer à la norme ANSI/NCSBCS A225.1/NFPA 501A.
Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique et peut être installé dans une maison préfabriquée (É.-U. seulement) ou mobile installée à demeure si les règlements
locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Une trousse de conversion est fournie avec cet appareil.
For Use Only with Barriers CV60E-1 (Part #940-519/P) Follow installation instructions.
Utiliser uniquement avec l'écrans CV60E-1 (n° 940-519/P) Suivre les instructions d'installation.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
Electrical supply / Alimentation électrique 115VAC, 2.5A, 60Hz.
Part No. 946-535 Power vent Horizontal Termination City Series may be used. La terminaison horizontale Power V ent City Series (pièce n°946-535) peut être utilisé
Part No. 666-945 Inline Power vent City Series may be used. La terminaison en ligne Power Vent City Series (pièce n°666-945) peut être
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS. CATEGORY I.
FOYER AU GAZ À ÉVACUATION -
Model/Modèle :
CANADIAN ENERGY
CSA P.4.1 Fireplace Efficiency (FE) / Efficacité énergétique des foyers (EEF) CSA P.4.1
PERFORMANCE
VERIFIED
Natural Gas / Gaz naturel 51.22%
RENDEMENT
Propane Gas / Gaz propane 51.96%
ÉNERGÉTIQUE
EP5011169
VÉRIFIÉ
Part #:
920-546
For the State of Massachusetts, installation
Colour:
Black on grey except what is indicated as being printed red.
and repair must be done by a plumber or
Size:
(File at 100%) 9.11"w x 6.27"h
gas fitter licensed in the Commonwealth of
Material:
Massachusetts.
Start serial sequence at 546000001
For the State of Massachusetts, flexible
June 08/22:
Created draft
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the
appliances individual manual shut-off must
be a t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
6
|City Series CV60E-1
é ANSI Z21.88-2019 • CSA-2.33-2019
CSA 2.17-2017
GAZ NATUREL : Modèle CV60E-NG1
Pression d'alimentation minimale
5.0"
WC/C.E. (1.25 kPa)
3.8"
WC/C.E. (0.94 kPa)
Pression de sortie (manifold) - Haute
1.1"
WC/C.E. (0.27 kPa)
Pression de sortie (manifold) - Basse
# 32
DMS
Taille de l'orifice
39,000 Btu/h
(11.42 kW)
D bit calorifique maximal
é
21,000 Btu/h
(6.15 kW)
D bit calorifique minimal
é
0-4500
ft/pi
(0-1372 m)
Altitude
GAZ PROPANE : Modèle CV60E-LP1
11"
WC/C.E. (2.73 kPa)
Pression d'alimentation minimale
10.5"
WC/C.E. (2.62 kPa)
Pression de sortie (manifold) - Haute
2.9"
WC/C.E. (0.72 kPa)
Pression de sortie (manifold) - Basse
# 50
DMS
Taille de l'orifice
36,000 Btu/h
(10.54 kW)
D bit calorifique maximal
é
19,500 Btu/h
(5.71 kW)
D bit calorifique minimal
é
Altitude
0-4500
ft/pi
(0-1372 m)
NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE. CATÉGORIE I.
CV60E-NG1

Decal Location

Remove the centre access panel on the outer trim. Data plate
will be next to the gas valve, as shown below.
Remove
Duplicate S/N
FOYER AU GAZ À ÉVACUATION
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
DOIT ÊTRE UTILISÉ UNIQUEMENT AVEC LES PORTES VITRÉES CERTIFIÉES
CV60E-LP1
DETAIL A
SCALE 1 : 12
579
Serial No./ No de série
579
Minimum Clearances to Combustibles /
Dégagement minimaux par rapport aux matériaux combustibles
Min. 180 in
2
Side Walls / Murs latéraux
A
Ceiling / Plafond
B
52" (1321 mm)
Min. Mantel Height /Hteur Min
Manteau
B
D
F
C 9" (229 mm) with 12" mantel
Max. Mantel Depth/Profondeur Max
A
C
Manteau
D
Alcove Width/Largeur Alcôve
E
E
Alcove Depth/Profondeur Alcôve
DOOR SEAL: Please
F
check that the door is
(See instruction manual for detailed instructions)
properly sealed
(Voir manuel pour plus de détails)
This vented gas fireplace heater is not for use with air filters.
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
e.
utilisée.
Decal
8" (203 mm)
12" (305 mm)
109.5" (2781 mm)
35" (889 mm)
FPI Fireplace Products
International Ltd.
Delta, BC, Canada
Made in Canada
Fabriqué au Canada