Procedure When Installing The Motor - Siemens SIMOTICS L-1FN3 Configuration Manual

Linear motors peak and continuous load motors
Hide thumbs Also See for SIMOTICS L-1FN3:
Table of Contents

Advertisement

Configuration
5.4 Mounting
Screw-in depths for the secondary section installation
Minimum permissible screw-in depth
The minimum permissible screw-in depths for the most commonly used materials for a
machine bed are listed below. For different materials, you must determine the screw-in depth
according to VDI Directive 2230.
Table 5- 2
Material
EN GJL-250
EN GJL-300
EN GJS-600-3
G-ALZN10Si8Mg
St 37
St 50
Maximum screw-in depth
The maximum screw-in depth is at the discretion of the machine manufacturer.
The maximum screw-in depth is specified by the threaded holes in the customers machine
bed.
5.4.4

Procedure when installing the motor

Installing a linear motor is subdivided into the following steps:
1. Check the installation dimension before installing motors
2. Clean the mounting surfaces for motor parts and the machine.
3. Installing primary sections, secondary sections and components
4. Checking the motor installation
142
Minimum permissible screw-in depths
Screw-in depth
1.4 • d
1.3 • d
0.7 • d
2.8 • d
1.8 • d
1.3 • d
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
1FN3 linear motors

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents