Electrical connection
8.3 System integration
Prefabricated adapter cables 6FX8002-5LMx0 with straight heavy-gauge threaded joint and
connector are available for the MOTION-CONNECT connection system, as are direct cables
6FX8002-5LMx5 without connector. These cables allow quick connection to the motor using
angular ring cable lugs and heavy-gauge threaded joints with an integrated EMC-compliant
shield support. You will find the article numbers for these items in the catalog or on the
Internet at https://eb.automation.siemens.com using the search term "MOTION-CONNECT".
Separate power and temperature sensor cables
This connection type is standard for peak and continuous load motors. The power cable has
4 power cores (3 phases and PE). The temperature sensor cable has 2x2 signal cores.
Connect both cables to the terminal panel. Insert the cables into the terminal panel with two
metric cable glands.
You will find connection types for connection of temperature sensors and core assignments
in Chapter "Signal connection (Page 500)".
Figure 8-7
492
PIN assignments of the plug-in connectors for signal cables
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
1FN3 linear motors