Procedure when installing the motor

Sequence for installing the motor
Risk of injury and material damage
Injury and/or destruction of motor components can occur if you do not observe the specified
sequence when installing the motor.
• Perform work steps in the specified sequence during installation.
128
Maximum permissible screw insertion depths for the stator and rotor
Component
WARNING
Max. permissible screw-in depth
in mm
8.5 + section without thread *)
11
10
12
13
12
15
15
Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
Thread
M6
M6
M5
M6
M8
M8
M10
M10