This is used to calculate the required line current I
I
Netz
If the Active Infeed is operated according to the factory setting, i.e. with a line-side power
factor of cosφ
can be simplified to
I
Netz
The Active Infeed must now be selected such that the permissible line current of the Active
Infeed is greater than or equal to the required value I
5.3

Examples

Note
The data used here may deviate from the values specified in Chapter "Technical data and
characteristics". This does not affect the configuration procedure, however.
5.3.1

Positioning in a specified time

Predefinitions
In the case of positioning in predefined time, only the end points of the path and the duration
of the individual motion sections are predefined.
Objective
An appropriate primary section of the peak and continuous load motors in the 1FN3 product
family, the matching secondary sections and the number of required secondary sections are
to be found for the following specifications:
The motor is to move on a horizontal axis during time Δt
there for time Δt
variables in a distance-time diagram.
1FN3 linear motors
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
= P
/ (√3 • U
• cosφ
Netz
Netz
= 1 , so that it draws only pure active power from the supply, the formula
Netz
= P
/ (√3 • U
).
Netz
Netz
and then return to the starting position. The following figure shows these
2
Netz
).
Netz
of the Active Infeed as follows:
.
Netz
to a specific point s
1
Configuration
5.3 Examples
. It is to wait