Configuration
5.4 Mounting
Figure 5-29
The Hall sensor box cable is trailable and can therefore be integrated into cable carriers.
5.4.6

Cooler connection

Connection system
Please note the following for the connection of the cooling system:
● All connections should be flexible (hoses)
● All material used must be resistant to the local environmental conditions
● All materials must be compatible
● Manufacturer's information regarding mounting are to be observed.
5.4.6.1

Primary section cooling connection

Preconditions for the connection
All cooling connections of the primary section main cooler and primary section precision
cooler have a G1/8 cylindrical pipe thread according to DIN ISO 228-1. Suitable connectors
are required for connecting the hoses.
NOTICE
Never use any used connection parts and components
Faulty and used connection parts and components can result in pressure drop and leaks.
• Use only new, unused connection parts and components
• Check the compatibility of the materials of the connection parts and components and
158
Specified dimension for mounting the Hall sensor box (HSB)
seals with respect to one another and the coolant used.
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
1FN3 linear motors