Connection of the temperature sensors via TM120
The terminal assignment for the channels of the temperature sensor inputs can be freely
selected on the TM120.
Table 8- 9
Conductor assignment for cable
6FX8002-2SL00- ....
white
brown
green
yellow
gray
pink
-
-
green/yellow
1FN3 linear motors
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
Terminal assignment for the temperature sensor inputs on the TM120 (example)
Duct / clamp
1
2
3
4
5
6
7
8
Protective conductor connection
on the shield connection plate
Electrical connection
8.3 System integration
Sensor contact
-1R2: -KTY or Pt1000
+1R1: +KTY or Pt1000
1TP1: PTC
1TP2: PTC
-
-
-
-
PE