Parallel Arrangement - Siemens SIMOTICS L-1FN3 Configuration Manual

Linear motors peak and continuous load motors
Hide thumbs Also See for SIMOTICS L-1FN3:
Table of Contents

Advertisement

Coupled motors
10.2 Master and stoker
Table 10- 3
Primary section type
Peak load motor
Continuous load motor
10.2.3

Parallel arrangement

The phase sequence U, V, W of the master and stoker is identical because the cable outlet
direction is the same. When the positioning of the master and stoker is correct, the pole
layout is identical on the two primary sections.
In the parallel arrangement, you can offset the primary sections by the distance A or the
secondary section tracks by the length B, if required.
Note
Offset factor
The offset factor i is an integer factor only.
576
Minimum distances between master and stoker
Same length
1FN3050-xW
1FN3100-xW
1FN3150-xW
1FN3300-xW
1FN3450-xW
1FN3600-xW
1FN3900-xW
1FN3050-xN
1FN3100-xN
1FN3150-xN
1FN3300-xN
1FN3450-xN
1FN3600-xN
1FN3900-xN
Distance between
housings D
3.5 mm
10.2 mm
25.5 mm
46.2 mm
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
Minimum distance M
72.5 mm
111.2 mm
102.5 mm
157.2 mm
1FN3 linear motors