Temperature sensor connection – standard
Connect the signal cable as follows:
● Using a plug connector at the SME12x (Sensor Module External)
● With open cable ends at the TM120
The SME12x or the TM120 is connected to the converter via DRIVE-CLiQ. See the diagrams
for "System integration (Page 486)".
Note
Checking the shutdown circuit
Before commissioning and switching on for the first time, carefully check that the Temp-S
temperature monitoring circuit correctly shuts down the system when it responds via the
SME12x or the TM120.
Typical characteristic R(ϑ) of a PTC temperature sensor according to DIN 44081 is provided
in Chapter "Technical features of temperature sensors (Page 88)".
Connection of the temperature sensors via SME12x
1FN3 linear motors
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2