1FN3300-4WC00-0xAx
Technical data
Secondary section cooling data
Maximum dissipated thermal output
Recommended minimum volume flow rate
Pressure drop per meter of heatsink profile
Pressure drop per combi distributor
Pressure drop per coupling point
292
Designation
Q
S,MAX
V̇
S ,MIN
Δp
S
Δp
KV
Δp
KS
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
Unit
Value
kW
0.144
l/min
5
bar
0.138
bar
0.651
bar
0.474