Siemens SIMOTICS L-1FN3 Configuration Manual page 91

Linear motors peak and continuous load motors
Hide thumbs Also See for SIMOTICS L-1FN3:
Table of Contents

Advertisement

Technical features of the KTY 84 temperature sensor
The KTY 84 has a progressive temperature resistance characteristic that is approximately
linear. In addition, the KTY 84 has a low thermal capacity and provides good thermal contact
with the motor winding. The KTY 84 has a continuous characteristic.
Table 4- 2
Name
Type
Transfer range
Resistance when cold (20 °C)
Resistance when warm (100 °C)
Characteristic of a KTY 84
1FN3 linear motors
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
Technical data of the KTY 84 PTC thermistor
Description
KTY 84 according to EN 60034-11
-40 °C ... +300 °C
ca. 580 Ω
ca. 1000 Ω
Motor components and options
4.1 Motor components
89