Testing the Diode Assembly (continued)
Electrical System: Testing the Electrical Components
3. The diode
(Figure
190) can be tested by using a digital multimeter (diode test
or ohms setting) and the
4. Replace the diode assembly if testing determines that the diode is damaged.
5. After you complete the testing, ensure that the diode is fully installed into the
wire harness connector and secured to the harness with cable tie.
Diode Test Table
Multimeter Red Lead (+)
on Terminal
Female
Male
Diode Test Table (page
Multimeter Black Lead
(-) on Terminal
Male
Female
Page 5–84
5–84).
Continuity
Yes
No
Groundsmaster
®
16226SL Rev C
4300-D