Machine Faults (continued)
Groundsmaster
®
4300-D
16226SL Rev C
The faults screen
(Figure 137
that have occurred since the faults were last cleared from the InfoCenter. The
faults will be identified by a number code and when the fault occurred. The faults
that might occur on the machine are listed in the
If a machine fault occurs during operation, the InfoCenter fault indicator will blink
to notify the operator, and machine functionality may be affected due to the fault.
To regain full machine functionality:
1. Disengage the cutting deck, release the traction pedal.
2. Turn the key switch O
3. Allow the machine to remain O
4. Restart the engine and check the machine operation.
5. If a fault continues to occur, further system evaluation and possible
component repair or replacement will be necessary.
To view a description of a fault that has occurred since the faults were last
cleared from the InfoCenter, press the down button (as indicated by the
the bottom of the screen) to highlight the desired fault, then press the left/right
button (as indicated by the
To return to the previous screen, press the menu/back button (as indicated by
the
at the bottom of the screen).
Clear System Faults (PIN required) If the correct passcode (PIN) has been
entered (refer to the Protected Menus in the
InfoCenter fault log can be cleared by selecting Clear System Faults. The cleared
faults will be removed from the InfoCenter list but will be retained in the TEC
memory. Contact your Toro Distributor to view faults stored in the TEC memory.
and
Figure
138) will list all machine electrical faults
and allow all machine functions to stop.
FF
for at least 1 minute.
FF
).
Settings Screen (page
Page 5–15
Machine Faults (page
5–30).
5–21)) the
Electrical System: InfoCenter Display