Check Signal Strength Between The Gbe Ro Controller And Remote - Culligan G1 Series Installation, Operation And Service Instructions

Reverse osmosis water treatment systems
Table of Contents

Advertisement

Check Signal Strength Between the GBE RO Controller and Remote

Check the signal strength once the RO controller and wireless remote are set up.
RUNNING
JAN-01-12
12:01P
1) GO TO RUNNING
2) GO TO OFFLINE
3) INFORMATION
>4) SETUP
3) POWERON MODE
4) FLUSH MODES
5) ACCESSORIES
>6)DIAGNOSTICS
>1) TST WIRELESS
2) TESTPHONELIN
3) USE DATA PORT
4) TEST APP
WIRELESS TEST
0 / 188
RSSI=5
RUNNING
JAN-01-12
12:01P
Culligan® Series G1 Reverse Osmosis
44
1.
From the default home screen, press
2.
Press
to scroll to 4) SETUP.
3.
Press
to select the SETUP menu.
4.
Press
5.
Press
to select 1)TST WIRELESS. The screen displays the wireless test
screen.
6.
The screen displays the test number and total number of attempts and the re-
ceived signal strength indicator (RSSI). The system will continue to test the signal
strength until you press any button to return to the diagnostics menu.
The signal strength indicator (RSSI) will show a value of between 0 and 8. If the
RSSI is at least 4, then the installation is complete. It the SSI drops below 4, then
it may be necessary to select an alternate location for the wireless remote.
7.
Press
to save the settings and return to the home screen.
. The screen displays the main menu.
to select 6)DIAGNOSTICS.
Cat. No. 01021713
44