Modem

NOTE
The modem can be installed into either the back of the RO controller or the back of the remote control
board. The functionality of the modem is the same in either installation.
NOTE
Use of the modem kit requires a one-year subscription to either a Level 1 or Level 2 Telecom package.
Self-service registration is available at www.myculligan.com.
1.
Before installing the modem into the back of the RO Controller board or the back of the remote, the RO
Controller circuit board or the remote must first be powered off.
2.
When handling all circuit boards, take care to only touch the edges of the circuit boards—not the metal pins.
The electronics on all circuit boards can be damaged by static electricity.
3.
Make sure all of the pins at all four connectors are aligned between the modem board and the main controller
board. Make sure that the modem board is fully seated into all four sockets.
4.
When all connections have been made restore power.
5.
Connect the modem to the telephone line by plugging a standard RJ-11 phone extension cord into the modem
board.
NOTE
The GBE RO Controller is designed to plug into an analog telephone line (standard residential phone
line). This includes phone lines connected to most residential VoIP (voice over Internet) phone sys-
tems and to residential DSL phone systems. If you are connecting the RO to a DSL phone system,
follow the DSL provider recommended method to connect standard phones to the DSL service. Many
systems recommend or require the use of DSL line filters between the phone jack and the device.
NOTE
Try to place the RO Controller or Remote Display near a telephone jack. A splitter might be needed if
the jack is already in use.

Installing the Modem on the GBE RO Controller Board

Open the controller cover and locate the modem connection on the back of the board (see Figure 26). Insert line modem
board (part number 01020307) into the socket on the back of the board. Make sure that all of the pins in all four connec-
tors are aligned and make sure the modem is fully seated into all of the sockets.
Cat. No. 01021713
Figure 26.
Back of GROC board.