Wiring for Softeners and Filters with GBE RO Controller
For these systems, you must add a 24 VAC relay, part number 01016156, to provide the pretreatment contact.
GBE to Relay: Connect a wire from terminal 5 of the relay to the left terminal of Aux 4 on the GBE softener/filter circuit
board. Connect another wire from terminal 1 of the relay to the right terminal of Aux 4. Refer to
Relay to GBE RO controller: Connect a wire from the POSITION (J2), PIN 3 terminal on the AUX board to terminal 3 on
the relay. Connect another wire from the POSITION (J2), PIN 4 terminal on the AUX board to terminal 4 on the relay. Use
the GBE RO controller Aux cable kit, P/N 01021830, to connect cables to the GBE RO controller board.
J5
J6
J17
J16
AUX OUT 4
Cat. No. 01021713
J7
GBE SOFTENER/FILTER
J10
J2
Relay
GROC BOARD
Figure 19.
GBE to GBE RO controller relays.
Figure
19.
First Time Setup
29