4.
Remove a new membrane from its plastic bag. Lightly lubricate the O-rings with a silicone-based lubricant or
use a mixture of 70% glycerin and 30% water.
CAUTION!
Do not use a petroleum-based lubricant. It will damage the synthetic rubber and the
membrane.
5.
Install the membrane in the same direction as indicated by the arrow on the outside of the membrane vessel.
The brine seal end should go in last.
6.
Repeat for the remaining membrane housings. There may be from one to four housings on each model.
G1 Tubing Configuration
A
FROM MEMBRANE
C
PRODUCT 1/2" TUBE
SYSTEM PRODUCT
OUTLET 1/2" TUBE
WARNING! The system must be grounded. An improperly grounded unit could cause injury from
electrical shock!
Culligan® Series G1 Reverse Osmosis
10
TO MEMBRANE
FEED (1/2" TUBE)
SYSTEM WASTE
(CONCENTRATE) 3/8" TUBE
Figure 9. G1 tubing configuration.
B
FROM MEMBRANE
CONCENTRATE 3/8" TUBE
SYSTEM INLET
1/2" TUBE
Cat. No. 01021713
10