Assembly

Concrete Wall Installation

Refer to Figure 3 to install the G1 RO system to a concrete wall. Place the unit against the wall, level the unit and mark
the wall through the mounting holes. Drill the holes in the wall and mount the unit. Horizontal holes are on 16" centers.
Vertical holes are on 2" centers.
Wall Mounting Kit (optional)
If the wall is not concrete and wall mounting is necessary, a wall mounting bracket kit is available. The bracket has holes
for mounting on 18" and 20"centers. Use bracket P/N 01023017 for all models.
Place the bracket adapter on the wall with the flat side towards the wall. Level the bracket adapter and mark the wall
through the appropriate holes. Drill holes in the wall. Assemble the wall brackets to the bracket adapter. Mount the adap-
ter and wall brackets to the wall. Mount the pump/motor assembly and the membrane assembly to the brackets.
Figure 3. G1 RO wall mount bracket kit, P/N 01022077 (included with unit) and optional bracket adapter.
Stand Mounting (optional)
If the RO unit requires floor mounting, a rigid steel stand (P/N 01021987, Figure 4) is available. Wall mount brackets are
used with floor stand to mount unit and membranes.
LANYARD
Cat. No. 01021713
Align with 20" studs
Align with 18" studs
Mounting
Bracket
Figure 4. G1 RO floor assembly.
Mount
To Wall
Wall Mount
Bracket Adaptor
NOTE DIRECTION
ANGLED FACE UP
BOLT HEADS
THIS SIDE
NOTE DIRECTION
ANGLED FACE UP