Error Limits

Setting Error Limits

Limits can be set for various operating parameters. If these limits are exceeded, the GBE RO Controller will trigger an
error message and shut down the RO system. User intervention is required to restart the RO system. If the modem option
is installed, this error will be transmitted when the system calls in.
RUNNING
JAN-01-12
12:01P
1) GO TO RUNNING
2) GO TO OFFLINE
3) INFORMATION
>4) SETUP
4) FLUSH MODES
5) ACCESSORIES
6) DIAGNOSTICS
>7) ERROR LIMITS
Error Limits Settings
Press
or
and then
Screen Display
MAX RECOVER%
90%
MIN RECOVER%
10%
MAX IN TEMP
120F
MIN IN TEMP
33F
MAX TDS OUT
250
PPM
Culligan® Series G1 Reverse Osmosis
58
1.
From the default home screen, press
2.
Press
to scroll to 4) SETUP.
3.
Press
to select the SETUP menu.
4.
Press
to change the value if necessary.
Range
The system's recovery changes as operating parameters fluctuate
and membranes age. Set this value to the maximum allowable re-
0–100
covery. As the recovery increases, product quality decreases (TDS
increases).
Set this to trigger an alarm if the recovery falls below the setting. A
0–100
very low recovery can indicate membrane fouling or a mis-adjusted
system.
0–200
This is the maximum allowable temperature for the system.
33–100
This is the minimum allowable temperature for the system.
Select the highest total dissolved solids in the product water (low-
est product quality) accepted by the G1 or M2 RO. Product water
1–500
that exceeds the maximumTDS level will trigger an error condition,
HIGH TDS OUT (see
. The screen displays the main menu.
to select 7)ERROR LIMITS.
Procedure
page
63).
58
Cat. No. 01021713

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G1-2sG1-3lG1-4lG1-1fG1-2fG1-3s ... Show all

Table of Contents