6.
Remove the end of concentrate tubing from the drain and place it in the solution tank.
7.
Choose GO TO RUNNING from the main menu. Allow the acid solution to circulate for 30 minutes. During recir-
culation, monitor the pH of the solution. If the pH rises above 3.0, add acid to reduce the pH to 2.0.
CAUTION!
The temperature of the chemical solution will rise as it is recirculated. If the temper-
ature exceeds 95°F, turn the power switch to OFF and allow the solution to cool to
prevent damage to the RO elements.
NOTE
A plastic gallon jug filled with ice may be placed in the solution to cool it.
8.
When 30 minutes have passed, adjust the system pressure to the pressure recorded in Step 9. Measure the
product flow rate, then compare this flow to the flow recorded in Step 9. If cleaning is successful a noticeably
higher product flow should now be observed.
9.
Choose GO TO OFFLINE from the main menu. If the cleaning was for removal of hardness scale or iron only,
go to "Finish Cleaning Procedure"

Clean Silt or Biofouling

1.
If the cleaning was for silt or biofouling, take a 250 ml sample of phosphoric acid solution and carefully add
sodium hydroxide until the pH is at least 12. If the solution turns cloudy, it contains hardness and/or iron.
Discard the contaminated acid and prepare a fresh 30 gallons of phosphoric acid solution.Add sodium hydroxide
to the phosphoric acid solution. The pH of the solution should be increased to 11.0-11.5.
NOTE
The result is an alkaline solution of tri-sodium phosphate (TSP), a common ingredient in detergents.
2.
If the solution remains clear, then direct the concentrate tubing to drain, then choose GO TO RUNNING from
the main menu. Check that the unit is drawing chemical solution.
CAUTION!
If the pump is noisy, cavitation is occurring and the pump will be damaged. Choose
GO TO OFFLINE from the main menu and check for any obstructions to flow. Reduce
the pump pressure as required to prevent cavitation..
3.
After approximately 5 gallons have been drawn from the solution tank, choose GO TO OFFLINE from the main
menu.
4.
Allow the elements to soak for 15 minutes. Turn the power switch to ON. Draw another 5 gallons from the solu-
tion tank. Choose GO TO OFFLINE from the main menu.
5.
Remove the end of concentrate tubing from the drain and place it in the solution tank. Choose GO TO
RUNNING from the main menu. Allow the alkaline solution to circulate for 30 minutes. During recirculation moni-
tor the pH of the solution. If the pH drops below 10.0 add sodium hydroxide to increase the pH to 11.5.
NOTE
If the caustic solution becomes dark brown (like coffee), it probably is saturated with organic material.
Discard the solution and prepare a fresh batch of phosphoric acid and sodium hydroxide.
For more accurate testing, use a Hach Model DE-2 detergent test kit or equivalent to ensure that the
product water is less than 0.05 ppm detergent.
A plastic gallon jug filled with ice may be placed in the solution tank to cool the solution.
CAUTION!
The temperature of the chemical solution will rise as it is recirculated. If the tempera-
ture exceeds 95°F, choose GO TO OFFLINE from the main menu and allow the solution
to cool to prevent damage to the RO elements.
Culligan® Series G1 Reverse Osmosis
74
Cat. No. 01021713
74