Culligan Gold Arsenic Series Owner's Manual

Culligan Gold Arsenic Series Owner's Manual

Water conditioner

Advertisement

Quick Links

Culligan®
Gold Arsenic
Water
Conditioner
Owners
Guide

Advertisement

Table of Contents
loading

Summary of Contents for Culligan Gold Arsenic Series

  • Page 1 Culligan® Gold Arsenic Water Conditioner Owners Guide...
  • Page 2 We promise that you’ll never want to be without it again. Congratulations, too, on selecting one of the “first family” of water filters in the prestigious Culligan Advanced Gold Series. With Culligan’s many years of knowledge and experience in water treatment, you can be confident that the model you selected has been designed and engineered to provide years of service with a minimum of care and attention.
  • Page 3: Table Of Contents

    Performance Data Sheets are included in this manual for various Culligan Gold Arsenic Water Condi- Table of tioner models. Refer to the Performance Data Sheet for your specific filter, as there are slight differences Contents between the models. The filter warranty is located on page 23 of this Owner’s Guide.
  • Page 4: Specifications

    Specifications Culligan Gold Arsenic Performance Specifications 10-inch System 12-inch System 14-inch System General Control Valve 1” Reinforced Thermoplastic Timer Electronic GBE Overall Conditioner Height 63 in. 61 in. 74 in. Media tank Design Quadra-Hull Tank Media Tank Dimensions (Dia x Ht) 10 x 54 in.
  • Page 5: Conditioner Operation

    Settings The Culligan Automatic Water Filter is designed to perform efficiently on a wide range of water supplies. In order to ensure proper operation of the filter, and before initiating the initial recharge and putting the unit into service, the following settings need to be made.
  • Page 6: Navigating The Menus And Keypad

    Navigating the Menus and Keypad UP button CHECK MARK CANCEL (X) button or OK button DOWN button UP ARROW button: scrolls up the menu DOWN ARROW button: scrolls down the menu CHECK MARK button: selects the highlight- ed option, opens a new screen, or accepts a Controller changed setting CANCEL or X button: returns to the previous...
  • Page 7 10. The screen displays the HOME SCREEN. NOTE Unplugging the Culligan Gold Arsenic water conditioner will not affect any of the control settings (the control must be plugged in for at least 10 minutes). Once programmed, the settings will be stored indefinitely.
  • Page 8: First Time Set-Up Process

    If this unit will be installed with a modem, it is MON DD YEAR required that this electronic ID number be reported to Culligan on the IQR form. Set Month (Jan–Dec) The screen displays the month setting. Press to accept the information >JAN...
  • Page 9 Set Hour (12PM–11AM) SET HOUR The screen displays the hour setting. Press to accept the information >12PM displayed (and view the next setup screen), or press to change the setting. Press to change the hour (in this example, from 12PM to 10AM). to accept the selected hour and advance to the next setting, SET Press MINUTES.
  • Page 10 When the total flow reaches total capacity, the filter GALLONS initiates reconditioning at the preset time. NOTE Culligan recommends using REGEN INTERVAL (Time Clock Backup) even if a meter is used to inititate reconditioning. Press and then to change the setting.
  • Page 11: Set Date And Time

    Set Date and To update the date and time on the Gold Arsenic, follow this procedure. Time Screen Display Range Setting Description FILTERING Start at the HOME SCREEN. Press to advance to the JAN-01-13 11:19A MAIN MENU SCREEN. >1)INFORMATION 2)MANUAL MODE Press to scroll to 3) SET DATE/TIME.
  • Page 12 Screen Display Range Setting Description Set Clock Type 12. Press to advance to the next setting if the clock type CLOCK TYPE 12 or 24 is correct, or press and then to change the clock >12 HR type setting (leave at default setting, 12 hour). 13.
  • Page 13: Information

    Information The following information can be displayed at the control valve or remote display. These settings are read- only. Press to scroll through the settings. Press to view the previous setting. Screen Display Range Setting Description FILTERING JAN-01-13 11:19A From the HOME screen, press to view the main menu.
  • Page 14 Screen Display Range Setting Description NEXT REGEN ON The screen displays the date of the next regeneration, JAN-03 based on average daily water usage. Press to see the next information screen. TOTAL WATER USED 10. The screen the total water used for this configuration. 0–no 1000 Whole numbers are displayed above 100 gallons.
  • Page 15: Manual Regeneration

    Manual There are several conditions that will cause the control to trip a regeneration. The screen displays RE- GEN TONITE when the control has signaled for a regeneration. REGENERATING is displayed while the Regeneration control is in regeneration. The following are conditions that will call for regeneration: When the Soft-Minder meter has recorded the passage of a predetermined number of gallons.
  • Page 16 Standard Manual Regeneration Screen Display Range Changing the Setting Filtering JAN-01-13 12:01P This is the HOME SCREEN. Press any button except advance to the MAIN MENU SCREEN. 1)INFORMATION >2)MANUAL MODE Press to 2)MANUAL MODE then press . The 1–6 3)SET DATE/TIME screen displays the Manual Mode settings.
  • Page 17: Care And Cleaning Of Your Water Conditioner

    DANGER! If your unit should freeze, do not attempt to disassemble it. Call your Culligan Dealer. Important: Culligan water filters are sold for use on potable water, only. If at any time the water becomes contaminated, such as during a “boil water” situation, the operation of the water filter should be discontinued until it is verified that the water is again potable.
  • Page 18: Things To Check Before You Call For Service

    (outside tap) to see if you have any water pressure. If you have water pressure, check the bypass valve. If it is in the Service position, put it into the bypass and call your Culligan dealer for service.
  • Page 19: Error Codes

    Comment/ Clearing Error Message This message is displayed if an error Call the number shown. If possible, place this call using Call Culligan at has been detected that requires ser- a phone that will allow you to see and enter changes to...
  • Page 20: When And How To Bypass Your Water Conditioner

    If you are going away on vacation and want to save salt by not having the unit recharge while you’re away. Bypass Valve In the back of Culligan water conditioners is a push-button Cul-Flo-Valv® Bypass. To bypass unit, simply turn the blue knob clockwise. To return to service, reverse the procedure—turn the blue knob counter- clockwise.
  • Page 21: Performance Data Sheet Culligan Gold Arsenic 10

    Performance Culligan knows the more informed you are about your water treatment systems, the more confident you will be about its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is Data Sheet providing this Performance Data Sheet to its customers.
  • Page 22: Performance Data Sheet Culligan Gold Arsenic 12

    Performance Culligan knows the more informed you are about your water treatment systems, the more confident you will be about its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is Data Sheet providing this Performance Data Sheet to its customers.
  • Page 23: Performance Data Sheet Culligan Gold Arsenic 14

    Performance Culligan knows the more informed you are about your water treatment systems, the more confident you will be about its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is Data Sheet providing this Performance Data Sheet to its customers.
  • Page 24: Arsenic Fact Sheet

    Some laboratories may also be able to analyze specifically for (speciate) the form(s) of arsenic present in a water sample if requested. The Culligan Smart Filter Arsenic Reduction Automatic Water Conditioner is designed to reduce arsenic: both pentavalent and trivalent forms of arsenic. This treatment system was tested under laboratory condi- tion as defined in NSF/ANSI 53 Drinking Water Treatment Units - Health Effects and was found to reduce influent arsenic challenge concentration 0.050 mg/L arsenic consisting of either pentavalent or trivalent...
  • Page 25 Page left intentionally blank. 01021568...
  • Page 26: Culligan Limited Warranty

    If a part described above is found defective within the specified period, you should notify your indepen- dently operated Culligan dealer and arrange a time during normal business hours for the dealer to inspect the water conditioner on your premises. Any part found defective within the terms of this warranty will be repaired or replaced by the dealer.
  • Page 27 That’s why our 1,350 independently operated dealers worldwide don’t just sell products; they sell water quality you can count on. We stand behind our products with written limited warranties and our unequaled Culligan service. No matter where you live, you can depend on Culligan expertise to work for you—today and tomorrow.

This manual is also suitable for:

Gold arsenic 10"Gold arsenic 12"Gold arsenic 14"

Table of Contents