Flow Meter Settings - Culligan G1 Series Installation, Operation And Service Instructions

Reverse osmosis water treatment systems
Table of Contents

Advertisement

Flow Meter Settings

Screen Display
FLOW METERS
INSTALLED
FM1 K FACTOR
80.0
RUNNING
JAN-01-12
12:01P
12. Once all the desired flows are set, allow the system to run for approximately 30 minutes, and then record the
following measurements using the units gauges (U), GROC information screens (G), and your instruments (I):
a. Feed Flow Rate, gpm (G)
b. Feed Water Temperature, °F (I)
c. Feed Water SDI (I)
d. Feed TDS, ppm (I)
e. Inlet Pressure, psig (U)
f. System (pump outlet) pressure, psig (U)
g. Product TDS, ppm (G)
h. Product Flow, gpm (G)
i. Product Temperature, °F (G)
j. Product Pressure, psig (I)
k. Concentrate (waste) flow, gpm (a–h)
l. % Recovery (see
m. % Rejection (see
TCF = Temperature Correction Factor. Refer to
1
NOTICE
The Global RO Controller has a feature which records historical data. The intial startup data is kept
in the controllers memory. It is still a good idea to record the values on a separate sheet of paper
and keep the data near the unit in case of electrical problems.
13. Choose GO TO OFFLINE from the main menu. Connect the product tubing to the service plumbing.
14. Test the operation of the pressure switch by closing the inlet water supply valve. The unit should shut off imme-
diately.
CAUTION!
If the unit does not shut off, turn the unit OFF immediately to prevent pump damage.
Disconnect electrical power source, then check the wiring and replace the switch, if
necessary.
15. Open the inlet water supply valve. The unit should restart.
16. If connected, test the storage tank level control shutdown and the pretreatment lockout function.
Cat. No. 01021713
Range
The screen displays the installation status of the flow meter. Press
Installed
Not Installed
stalled in the RO system.
Press
0–9999
calculated value for the flow meter FM1 and/or FM2.
6.
Press
to save the settings and return to the home screen.
page
121)
page
121)
Changing the Setting
to change the state to installed if a flow meter is in-
or
and then
Table 2 on page 26
for this value.
to change the K-Factor to the
x TCF
=
1
First Time Setup
25