Wiring for Softeners and Filters with MVP Controller
For these systems, you must add a 24V relay P/N 01016156, to provide the pretreatment contact.
MVP to Relay: Connect a wire from Terminal 5 of the relay to the left terminal of P8 (Aux 2) on the MVP circuit board.
Connect another wire from terminal 1 of the relay to the right terminal of P8. Refer to
Relay to GBE RO controller: Connect a wire from the POSITION (J2), PIN 3 terminal on the AUX board to terminal 3 on
the relay. Connect another wire from the POSITION (J2), PIN 4 terminal on the AUX board to terminal 4 on the relay.
LCD
SW6 Dip Switch
MVP
P11
Battery
P6
Motor
P9 Power
P5
P8
2.5VAC 24V
Aux1
Aux2
P7 Sol
Valve
Culligan® Series G1 Reverse Osmosis
28
P3
Comm
P1
Aqua
Flow
Cam
Sensor
Meter
Relay
GROC BOARD
Figure 18.
MVP to GBE RO controller relays.
Figure 18.
Cat. No. 01021713
28