Pressurized Storage Tank; Non-Pressurized Product Water Storage Tank; Direct Feed - Culligan G1 Series Installation, Operation And Service Instructions

Reverse osmosis water treatment systems
Table of Contents

Advertisement

Pressurized Storage Tank

The product water can be stored in a pressurized storage tank with the reverse osmosis unit controlled by a pressure
switch. Use the same components used for direct feed (see Figure 16). The pressure switch needs to be wired to the con-
trol panel as a float switch (see
able for the G1 under P/N D1013880 (110V) or P/N D1018976 (220V). Connect the product tubing to a bulkhead fitting at
the top of the storage tank such as P/N 01005095 (2-gallon), P/N 01004776 (3-gallon), or P/N 01004765 (9-gallon).

Non-Pressurized Product Water Storage Tank

Depending on the type of application, a level control may be required to turn the unit off when the storage tank is full.
Install the level control according to the instructions provided with the control. See
wiring." on page 105
for electrical connections.
NOTICE
If a repressurization pump is used, an additional level control is recommended to prevent the
pump from running dry if the storage tank is empty.
To maintain high water quality, a hydrophilic air vent filter, vacuum breaker, pop-off valve, ultraviolet lamp, and pressure
relief valve may be required.

Direct Feed

If the product water is to be used directly, without storage, a few precautions are necessary to prevent damage to the
elements. Install a pressure gauge, pressure relief valve, and a normally-open ("dump") solenoid in the product water
line as shown in Figure 16, or use pressurized storage kit (P/N D1013880). The pressure gauge will allow the operator to
monitor the product water pressure. The relief valve, which should be set to open at 40 psig, will prevent the product water
pressure from exceeding 40 psi. The dump solenoid will relieve all pressure when the unit is off.
Wire the direct feed/pressurized storage solenoid valve in parallel with the motor.
Valve SV4 closes when the RO pump runs; SV4 opens when the pump stops, allowing all membrane back proessure to
be relieved.
NOTICE
Product back pressure will decrease the net pressure pushing water through the reverse osmosis
elements. Therefore, the flow of product water will decrease.
Culligan® Series G1 Reverse Osmosis
18
Figure 57 on page 105
for G1 standard wiring). A pressurized water storage kit is avail-
Figure 16.
"GBE RO Controller Basic sub-panel
Direct feed connection.
Cat. No. 01021713
18