Panasonic ELC500 User Manual page 69

Table of Contents

Advertisement

[8] Through connection
Set to use the function to pass MEWTOCOL communication command from LAN port to serial port.
Item
(a)
Use through function
(b)
Communication method
(c)
Port No. (Local station)
(d)
Disconnect time with no
Communication
*1 Only when 'TCP/IP' is selected for communication method.
Point
When 'Use through function' of Through connection (COM0) is available, a command to
LAN port is passed to COM0.
Note
- Through function supports only MEWTOCOL communication.
- When the station number is EE, it doesn't through. It responses as ELC500.
Description
Select use the function or not.
<Initial> without check = not available
Set communication method.
<Initial> TCP/IP
<Set range> TCP/IP / UDP/IP
Set port number of LAN port to use for output a command to
serial port.
<Initial> Through connection(COM0): 60017
Through connection(COM1): 60018
Through connection(COM2): 60019
<Set range> 1 to 65535
Set disconnect time during the communication.
*1
Disconnection time exceeds the set time, it will disconnect
automatically.
<Initial> 60 sec
<Set range> 1 to 3600
61