Acura NSX 1997 Service Manual page 374

Table of Contents

Advertisement

Main Menu
ATF Pump
The external tooth gear type ATF pump consists of a housing together with the main valve body, a pump drive gear, a
pump driven gear, and a pump shaft. The ATF pump is installed on the torque converter housing. The pump's driving
force is transmitted by the torque converter pump (directly connected to the engine) to the pump shaft. The intake and
exhaust lines, and the torque converter line are incorporated in the housing.
One-way Relief Valve
The one-way relief valve is used during high speed or high temperature to send fluid to the ATF cooler for ATF cooling.