Structure and function
SV 125
4016589
After venting, the vacuum insertion rod holder moves up and the table moves to
the next position.
When the stopper insertion process has ended, the valves of the vacuum line are
closed and the vacuum insertion rod holder is vented, to release the filling heads
from the syringes. Sterile air or nitrogen can be used for venting.
2 vacuum sensors are installed in the vacuum pipe system.
One of these sensors monitors the vacuum in the vacuum tank, the second sensor
monitors the vacuum in the syringe.
These sensors continuously check, if sufficient vacuum is present.
If the vacuum falls under a presettable value, the machine stops and an alarm mes-
sage appears on the operator panel.