Troubleshooting
SV 125
4016589
Alarm 16000
Final position not reached nest swivel arm
Final position not reached tub stopper infeed01
Final position not reached tub stopper lay down
Final position not reached tub stopper pick- -up
Final position not reached vacuum chamber
Cause
The respective cylinder has not
reached its final position.
Compressed air is missing.
The final position sensor is misadjus-
ted or defective.
Alarm 30001
Motor protection switch triggered
Cause
The release current of the motor cir-
cuit breaker is not correctly set.
Motor is defective.
Alarm 30002
PLC-Battery low PLC
Cause
The battery is flat.
Action
Eliminate blockage.
Search and eliminate the cause of
lack of compressed air.
Ensure that the compressed air lines
and connections are tight.
The compressed air manometer must
read at least 6 bar.
Adjust final position sensor and
replace it, if defective.
Action
Check the setting on the motor circuit
breaker.
Check motor.
Action
Replace the battery in the control cab-
inet.
Version 1.0
8--5