Infeed centering position [mm]
Position of the X--Y--table on the Y--axis during the centering process.
Infeed centering speed [%]
Speed with which the X--Y--table moves on the Y--axis during the centering pro-
cess.
Infeed wait position [mm]
Position of the X--Y--table on the Y--axis in waiting position.
Infeed wait speed [%]
Speed with which the X--Y--table moves to waiting position.
Changing a parameter
Determine the value through teach--in, see chapter 5.2.60, page 5--137.
1
Touch the input field of the parameter that should be changed.
2
Enter the determined value on the keyboard.
3
Touch control field
4
Control field
Screen Format input - - Menu teach servo axes is called up.
Screen Format input - - Tub transfer [help] is called up.
The screen serves for information only.
The machine drive is switched off.
Screen Main screen is called up.
The previous screen is called up.
Screen Format input - - Tub transfer [3/4] is called up.
on the keyboard to take over the entry.
Function
Version 1.0