Troubleshooting
SV 125
4016589
Alarm 61600
Waiting for amplifier axis insertion rod
Waiting for amplifier axis insertion tube
Waiting for amplifier axis needle stroke
Waiting for amplifier axis pickup station nest
Waiting for amplifier axis pump rotation
Waiting for amplifier axis pump stroke
Waiting for amplifier axis swivel arm
Waiting for amplifier rack 1
Waiting for amplifier rack 2
Waiting for amplifier X- -Axis
Waiting for amplifier Y- -Axis
Cause
The message appears when the
control voltage has been switched off
and on again.
Alarm 65014
Value out of tolerance range vacuum leak test filling system
Value out of tolerance range vacuum leak test stopper system
Cause
Leakage during leak test.
Action
Wait until the servo controller is ready to
operate.
The waiting time is approx. 60 s.
When the servo controller is ready to
operate, the message disappears.
Action
Search and eliminate the position of
the leakage.