Troubleshooting
SV 125
4016589
Alarm 30300
Fault communication operating panel
Cause
No communication between operator
panel and PLC.
Cable disconnected or wire break.
Alarm 30404
Orientation wrong stopper in gripper
Cause
Stopper upside down in stopper turn-
ing device.
Action
Check cabling.
Locate and eliminate the cause of
fault.
The alarm must be reset.
If you cannot eliminate this fault,
please contact the company OPTIMA
GROUP pharma.
Action
Take stopper manually out of the stop-
per turning device.
Check stopper feeding system.