Inova SV 125 Operating Manual page 348

Fully automatic filling and closing machine for syringes
Table of Contents

Advertisement

Alarm 31039
Fault control unit linear track stopper
Fault control unit sorter stopper
Cause
Motor is defective.
Converter is defective.
Motor is overheated.
Wire break.
Alarm 35000
Monitoring light barrier stopper check
Monitoring sensor vacuum chamber filling
Monitoring sensor vacuum chamber stopper setting
Monitoring sensor vacuum tank filling
Monitoring sensor vacuum tank stopper setting
Cause
The indicated sensor is contamin-
ated, misadjusted or defective.
Alarm 41000
Vacuum missing pickup station nest
Cause
Vacuum missing or too low at the in-
dicated station.
Version 1.0
8--14
Action
Turn the POWER supply disconnecting
device off and on again.
Check motor and converter.
Let motor cool down.
Check cabling.
Action
Clean sensor.
Check sensor and replace it, if defect-
ive.
Check and adjust sensor.
Action
Search and eliminate the cause of
fault.
Check vacuum system.
Check vacuum pump.
Check vacuum cups.
Troubleshooting
SV 125
4016589