Inova SV 125 Operating Manual page 166

Fully automatic filling and closing machine for syringes
Table of Contents

Advertisement

180_
180_
Dosing start
General No. of step points
Enter the number of step points. If the number of step points is reduced, all addi-
tional step points are deleted. The needle stroke does not move to the deleted step
points any longer.
Step point no.
Selection of a step point.
Step point position [mm]
Entry of the step point position of the selected step point number.
Segment type
Selection of a filling curve for a step point. To each step point a segment type can
be assigned. Either a linear or cubic filling curve can be selected (see sketch be-
low). For the first step point we recommend a cubic curve, for all other step points
a linear curve.
Linear filling curve
Cubic filling curve
Version 1.0
5--80
Dosage
320_
250_
The range for the dosing start is between
180_ to 250_.
The dosing range is determined
within the area of 180_ to 320_.
Operation
SV 125
4016589